• Creation and imagination of custom connecting parts
  • JAPANESE

Problem resolution case studies Page 1

Introducing examples of solving various problems.

Case 1

Airtight rubber header

Customer's request

I want to make a connector connection to get signals from a board that is inside a unit that needs to be airtight.

ICREX proposal

We suggested a method of using rubber as the base of the header to make a connector connection while keeping the unit airtight.

Case 2

Reflow heat countermeasure

Customer's request

For components that cannot withstand reflow heat, we have to mount them on the board after reflow. We want to reduce the number of man-hours for this process.

ICREX proposal

Mount a socket that matches the components lead pitch and pattern onto the board, then mount the components onto the socket after reflow.

Case 3

Pitch conversion adapter

Customer's request

Our standard module lead pitch doesn't match our customer's motherboard pitch.

ICREX proposal

Connect to different pitch modules via a pitch conversion adapter connected to a pattern.

Related products : Conversion adapter

Case 4

Pin header different shape from base

Customer's request

When a header is attached to a circular board, the board needs to be made smaller, so there is a lot of dead space.

ICREX proposal

Make the base curved, maintaining the effective surface area and reducing the board size.
Because the header base uses substrate material CEM-3, it is freely customizable without any initial mold costs.

Related products : Full custom pin headers